No exterior wall stays perfectly dry. Wind-driven rain finds its way through panel joints, fixing points, window perimeters and the small gaps that open up as materials age. For decades, designers tried to seal every opening. Today, most building scientists agree that managing water is far more reliable than trying to block it completely. That is the thinking behind the rainscreen system. By separating the outer cladding from the structural wall with a drained, ventilated cavity, a rainscreen keeps most of the rain outside, gives any water that gets through a clear path out, and lets the wall dry. This guide explains how rainscreen systems work, what they are made of, and why fiber cement panels are widely used as the outer skin.
What Is a Rainscreen System?
A rainscreen system is an exterior wall assembly in which the cladding is installed in front of the building’s water-resistive barrier, with an air cavity between the two. The cladding, which is the “rainscreen” itself, sheds most of the rain and takes the brunt of UV radiation, wind and impact. Behind it, the cavity drains incidental water and allows air to circulate, while the air and water barrier on the backup wall forms the real line of defense against water entering the building.
This is the key difference from a face-sealed or barrier wall. A barrier wall depends on the outer surface and its sealant joints staying perfect; once a joint cracks, water has nowhere to go but inward. A rainscreen accepts that some water will pass the outer layer and is designed so that this water drains away and dries before it can cause damage. In other words, a rainscreen is not a waterproof wall. It is a two-stage system: the cladding reduces the water load, and the barrier behind it stops what remains.
This approach brings several practical benefits:
Lower risk of moisture damage. Keeping the structure and insulation dry reduces the risk of rot, mold, fixing corrosion and freeze-thaw damage.
Better thermal performance. Insulation can be placed continuously outside the structure, reducing thermal bridging, while the cladding shades the wall from direct sun.
Longer service life and easier maintenance. Damaged panels can usually be removed and replaced individually without disturbing the wall behind.
Design freedom. Panel size, color, texture and joint pattern can change without changing the performance logic of the wall.
Rainscreen systems are now common on both commercial and residential buildings. On offices, schools, hospitals and apartment towers, they are usually engineered as complete systems with metal sub-frames, continuous insulation and specified facade panels. On houses and low-rise apartments, a simpler version, typically vertical battens creating a drained gap behind siding or panels, delivers most of the same moisture protection at modest extra cost. Horizontal fiber cement weatherboards such as Siding Plank, with its cedar wood grain texture, suit this approach on low-rise homes. The principle is the same; only the scale and sub-frame differ.

Fiber cement cladding installed over a ventilated cavity
How Does a Rainscreen System Work?
A rainscreen controls water through four mechanisms that work together.
Water Deflection
The outer cladding intercepts most of the rain that strikes the wall. Panel overlaps, drip edges, sloped sills and well-designed joints keep the volume of water reaching the cavity small. The less water that gets behind the cladding, the less the rest of the system has to handle.
Drainage
Water that passes through joints or fixings runs down the back of the panels or the face of the barrier and leaves the wall through an open base or weep openings. Drainage is the most important function of all. Building science research on screened walls shows that rain-control failures are usually failures to drain, so a continuous, unobstructed drainage path matters more than any other detail.
Ventilation and Drying
Openings at the bottom and top of the cavity allow outside air to move behind the cladding, carrying away moisture from wet surfaces. On sun-exposed walls, this airflow is driven mainly by thermal buoyancy, as the sun warms the cladding and the air behind it, and to a lesser extent by wind. Field measurements in Sweden found an average cavity air velocity of about 0.2 m/s behind cladding fixed on vertical battens, and much lower velocities where horizontal vented battens obstructed the flow. The same research notes a trade-off: on clear nights, a ventilated cladding can cool below air temperature and collect condensation, which is another reason the cavity must drain as well as breathe.
Pressure Equalization
Vents also let the air pressure in the cavity follow the pressure outside, reducing the pressure difference across the cladding joints that can push water inward. In practice, this equalization is never perfect. Studies by Straube and Burnett found that well-vented walls with an airtight backup can moderate more than 90% of steady wind pressure, but performance falls under gusting winds and winds striking the wall at an angle. For this reason, many building scientists prefer the term “pressure moderation” and treat it as a helpful secondary effect rather than a substitute for drainage.
Key Components and Types of Rainscreen Systems
From the inside out, a typical rainscreen wall is built from the following layers:
Backup wall: the structural wall, such as concrete, masonry, steel framing or timber framing.
Air and water-resistive barrier: a continuous membrane or coating, lapped shingle-style so water runs outward, that stops both air leakage and liquid water.
Insulation: often continuous exterior insulation; mineral wool is common on mid-rise and high-rise projects because it is non-combustible.
Sub-frame: timber battens, galvanized steel channels or aluminum brackets and rails that carry the cladding and set the cavity depth.
Ventilated cavity: the clear air space between the insulation or barrier and the back of the panels.
Cladding panels: the rainscreen layer, such as fiber cement, metal, terracotta, high-pressure laminate or timber.
Accessories: base and head vents, insect mesh, flashings, trims and, in taller buildings, fire cavity barriers.
Drained and Vented vs. Back-Ventilated
In a drained system, the gap behind the cladding exists mainly to let water run out. A vented system adds openings at the base, allowing limited air exchange. A back-ventilated system has openings at both the bottom and the top, so air can flow continuously through the cavity. Back-ventilated walls dry faster and are the standard choice for facade panels on commercial buildings and in wet climates.
Open-Joint vs. Closed-Joint
Open-joint systems leave deliberate gaps between panels. They give a crisp architectural look and generous ventilation, but they let more water reach the barrier. Laboratory tests on panel facades have shown that open horizontal joints cannot fully stop water seepage and that the amount of water passing through increases as the joint gets wider. Open-joint designs therefore need a UV-resistant membrane and careful joint detailing. Closed-joint systems back or fill the joints with profiles, gaskets or overlaps, reducing the water that enters the cavity while still relying on drainage and ventilation behind the panels.
Cavity Framing Options
Vertical battens or rails create continuous vertical channels, the simplest route for both drainage and airflow. Horizontal rails are sometimes needed for vertical cladding layouts, but they should be vented, gapped or counter-battened so they do not trap water or block airflow. Adjustable aluminum bracket systems are common on commercial facades because they accommodate thick insulation and uneven substrates. For houses, thin plastic drainage mats can provide a small drainage gap behind siding where a full ventilated cavity is not practical.
Why Fiber Cement Panels Suit Rainscreen Cladding
The cladding is the most exposed layer of the wall, and the choice of panel shapes how the whole system performs. Exterior fiber cement boards have become one of the most common rainscreen cladding materials for several reasons.
Non-combustibility. A ventilated cavity can act like a chimney in a fire, so the combustibility of the cladding matters. Fiber cement is made predominantly from inorganic materials and is classified as non-combustible, whereas timber and many laminate products are combustible, and the fire performance of metal composite panels depends heavily on their core.
Moisture tolerance. Fiber cement does not rot, and it resists mold and insect attack. Research on cellulose-reinforced cement composites shows that repeated wetting and drying gradually reduces their toughness, so cladding that dries quickly after rain performs better over the long term. A back-ventilated cavity provides exactly that drying.
Dimensional stability. Low moisture movement keeps panels flat and joints consistent, although expansion allowances at joints are still required.
Weather durability. Quality boards are tested for freeze-thaw, heat-rain and soak-dry cycles, which matter for long-term exterior use.
Workability. Panels can be cut, drilled, perforated and routed with standard tools, so large formats and custom joint patterns are easy to achieve.
A common question is whether fiber cement cladding needs a rainscreen at all, since the panels themselves tolerate water. The answer depends on the wall behind the panels, not the panels alone. Sheathing, timber framing, insulation and metal fixings are far more sensitive to moisture than fiber cement, and every joint and fastener is a potential leak path. In rainy, exposed or harsh climates, on taller buildings, and wherever insulation sits outside the structure, a drained and ventilated cavity is strongly recommended and is often required by local codes or system approvals. Only small, sheltered, low-rise buildings can reasonably rely on a minimal drainage gap.
Cladboard as a Rainscreen Facade Panel
Cladboard is New Element’s high-density exterior fiber cement board, designed for decorative curtain walls and external insulated facades on commercial and residential buildings. Its properties meet the key demands placed on ventilated facade panels:
Density: ≥1.40 g/cm³
Water absorption: ≤28%
Moisture movement: ≤0.25%
Bending strength: ≥18 MPa oven-dry, ≥13 MPa water-saturated
Impact strength: ≥1.4 kJ/m²
Durability tests: freeze-thaw, heat-rain, warm water and soak-dry tests passed
Fire: non-combustibility tested to EN 13501 and AS 1530
Composition: 100% asbestos-free
Cladboard is a through-colored fiber cement board, so the color runs through the full thickness. Cut edges and minor chips show the same color as the face, an important advantage in open-joint facades where panel edges remain visible. The board is available in natural, polished and textured finishes, ten standard colors and custom colors, and can be cut or carved to custom shapes.
Standard sheets measure 2440 × 1220 mm and 3050 × 1220 mm, with thicknesses of 8, 9, 10, 12 and 15 mm. Thicker boards suit taller buildings, higher wind loads and wider support spacing, and the right fiber cement board thickness should be confirmed by structural calculation for each project. Cladboard has been used on facade projects in China, Australia, Europe and South America.
Design and Installation Considerations
A rainscreen only performs as well as its details. The following points deserve attention at the design stage.
Cavity depth. Research on ventilation drying has found that cavities shallower than about 10 mm significantly prolong drying. Guidance varies by region: some North American panel systems use cavities of around 10 mm, while UK guidance commonly specifies a 25 mm minimum, with deeper cavities for exposed or tall elevations; a commonly cited rule of thumb adds 1 mm of depth per meter of height above 25 m for continuous cavities. Local codes and the system designer have the final say.
Ventilation openings. Provide continuous openings at the base and head of every cavity zone, protected with insect mesh and kept clear of mortar, insulation and debris.
Sub-frame layout. Use vertical support members wherever possible. If horizontal rails are unavoidable, vent or space them so water and air can pass.
Joint design. Narrower open joints admit less water. Protect horizontal joints with profiles or overlaps where exposure is high, and follow the manufacturer’s expansion allowances.
Fixings. Use corrosion-resistant screws or rivets, respect minimum edge distances, pre-drill panels, and combine fixed and sliding points so the panels are not stressed by thermal movement of metal sub-frames.
Flashings. Detail window heads, sills, the wall base and parapets so water in the cavity is always directed outward, never behind the barrier.
Fire safety. On mid-rise and high-rise buildings, install cavity barriers at floor lines and around openings, and use non-combustible insulation and cladding as required by local regulations.
A rainscreen system protects buildings by managing water rather than fighting it: deflect, drain, ventilate and dry. A durable, non-combustible facade panel completes the system. Contact New Element to discuss Cladboard specifications, samples and facade details for your project.